Simplex Manual Pull Stations: 4099-9004, 4099-9006, and 2099-9756

The Simplex 4099-9004, 4099-9006, and 2099-9756 Manual Pull Stations provide dependable manual fire alarm activation for commercial buildings, hospitals, hotels, offices, schools, warehouses, residential developments, industrial facilities, and other fire protection applications.


Designed to allow occupants to manually initiate a fire alarm when smoke, fire, or another emergency condition is discovered, these pull stations offer different operating methods and system connection options. The 4099-9004 is an addressable single-action model, the 4099-9006 is an addressable double-action push-type model, and the 2099-9756 is a conventional double-action push-type model.


For fire alarm contractors, engineers, consultants, system integrators, building owners, and facility managers, selecting the correct Simplex manual pull station is important for ensuring compatibility, proper alarm reporting, dependable operation, and compliance with the approved fire alarm system design.


What Is a Manual Pull Station?

A manual pull station is a manually operated fire alarm initiating device installed along exit paths and other accessible locations.

When activated, the device sends an alarm signal to the connected fire alarm control panel. The control panel can then activate programmed notification and emergency-response functions, which may include:


  • Audible and visual alarm devices

  • Fire alarm annunciation

  • Building evacuation signals

  • Elevator recall

  • Door release

  • HVAC shutdown

  • Smoke-control functions

  • Fire department or monitoring-station notification


The exact system response depends on the approved fire alarm programming and cause-and-effect sequence.


Simplex 4099-9004 Addressable Single-Action Manual Pull Station

Simplex 4099-9004 addressable single-action manual pull station with red housing, key-operated reset, and pull-down fire alarm lever on a white background.

The Simplex 4099-9004 is an addressable single-action manual pull station designed for compatible Simplex fire alarm systems using IDNet or MAPNET II communications.

Activation requires the user to firmly pull the operating lever downward. Once activated, the lever remains extended to provide a clear visual indication that the station has been operated. An optional internal break-rod may also be used as a deterrent against unauthorized activation.

Key Features of the 4099-9004

  • Addressable single-action operation

  • Firm pull-down alarm activation

  • Integral individual addressable module

  • IDNet or MAPNET II communication compatibility

  • One address required per station

  • Eight-position DIP-switch addressing

  • Screw terminals for incoming and outgoing wiring

  • Alarm lever remains visibly extended after activation

  • Optional break-rod

  • Tamper-resistant key reset

  • Red housing with white raised lettering

  • Intended for indoor fire alarm applications


The addressable communication module continuously monitors the station status and communicates alarm or condition changes to the compatible Simplex fire alarm control panel.


Simplex 4099-9006 Addressable Double-Action Manual Pull Station

Simplex 4099-9006 addressable double-action manual pull station with red housing, push plate, pull-down lever, and key-operated reset on a white background.

The Simplex 4099-9006 is an addressable double-action manual pull station with a push-and-pull operating sequence.

To activate the device, the user must first push back the spring-loaded plate marked PUSH, then pull the alarm lever downward. This two-step action can help reduce accidental or unintended operation while maintaining a clear and accessible manual alarm function.

Key Features of the 4099-9006

  • Addressable double-action operation

  • Push-then-pull activation

  • IDNet or MAPNET II communication

  • Integral addressable monitoring module

  • One address per station

  • Eight-position DIP-switch addressing

  • Screw-terminal wiring connections

  • Visible alarm indication after activation

  • Tamper-resistant key reset

  • Red housing with white lettering

  • Suitable for areas where accidental activation may be a concern


The 4099-9006 is listed in Simplex documentation as an English-language double-action push-operated manual station.


Simplex 2099-9756 Conventional Double-Action Manual Pull Station


Simplex 2099-9756 conventional double-action manual pull station with red housing, push plate, pull-down lever, and key-operated reset on a white background.

The Simplex 2099-9756 is a conventional, non-addressable double-action manual pull station with push-type operation.

Unlike the 4099 addressable models, the 2099-9756 connects to a conventional initiating device circuit or compatible monitoring interface. The fire alarm panel identifies the alarm by circuit or zone rather than by an individual device address.

To activate the station, the user pushes the spring-loaded interference plate and then pulls the lever downward. Simplex documentation identifies the 2099-9756 as a general-alarm, double-action push-type model.


Key Features of the 2099-9756


  • Conventional non-addressable operation

  • Double-action push-and-pull activation

  • General alarm contact operation

  • Screw-terminal wiring

  • Pull lever remains extended after alarm activation

  • Optional internal break-rod

  • Tamper-resistant key reset

  • Red manual station housing

  • Suitable for conventional fire alarm circuits

  • Can be integrated into an addressable system through an approved monitor module


The 2099 Series is intended for general-purpose manual fire alarm applications and includes single-action, push-type double-action, and break-glass double-action configurations.


Comparison infographic of Simplex manual pull stations 4099-9004, 4099-9006, and 2099-9756, showing addressable single-action, addressable double-action, and conventional double-action models with operating methods, system types, applications, key points, and selection guide.

Main Difference


The 4099-9004 requires only one pull-down movement, making it suitable for applications where immediate and straightforward manual activation is preferred.


The 4099-9006 requires two actions—pushing the front plate and pulling the lever—which can reduce accidental activations.


The 2099-9756 uses a similar double-action operating method but is a conventional device. It does not communicate its own individual address directly to an addressable fire alarm control panel.


Addressable Versus Conventional Pull Stations


Addressable Manual Pull Stations

Addressable models such as the 4099-9004 and 4099-9006 communicate directly with a compatible Simplex fire alarm control panel.

Benefits may include:


  • Individual device identification

  • Precise location reporting

  • Easier troubleshooting

  • Device-level alarm monitoring

  • Simplified maintenance records

  • Integration with programmed system functions


The Simplex addressable models receive power and communications through the compatible IDNet or MAPNET II circuit and use one address for each station.


Conventional Manual Pull Stations

Conventional models such as the 2099-9756 operate as switching devices connected to a conventional initiating circuit.

Benefits may include:


  • Straightforward circuit design

  • Compatibility with selected conventional panels

  • Suitable replacement for existing conventional systems

  • Integration into addressable systems through approved monitor modules


The control panel normally identifies the activated zone or monitor-module address rather than the exact conventional pull station.


Benefits of Simplex Manual Pull Stations


Reliable Manual Alarm Activation

Manual pull stations allow occupants to initiate a fire alarm immediately when an emergency is discovered, even when an automatic detector has not yet activated.


Clear Visual Alarm Indication

After activation, the pull lever remains in the operated position. This provides a visible indication that the station has been activated.


Addressable Device Identification

The 4099-9004 and 4099-9006 can report their individual device addresses to compatible Simplex fire alarm control panels, helping responders and maintenance personnel identify the alarm location.


Reduced Accidental Activation

Double-action models require two deliberate movements. This added step may be useful in public spaces, schools, corridors, warehouses, and other areas where accidental contact is possible.


Key-Operated Reset

The stations require an authorized reset key to restore the lever and alarm switch to the normal position. This helps prevent unauthorized resetting after activation.


Flexible Mounting Options

Depending on the project configuration, Simplex manual stations may be installed using:


  • Surface-mounted back boxes

  • Semi-flush electrical boxes

  • Flush-mount adapter kits

  • Retrofit trim plates

  • Approved Simplex mounting accessories


Typical Applications

Simplex 4099-9004, 4099-9006, and 2099-9756 manual pull stations may be used in:


  • Commercial office buildings

  • Hospitals and healthcare facilities

  • Hotels and resorts

  • Schools and universities

  • Condominiums and residential towers

  • Shopping centers and retail facilities

  • Warehouses

  • Manufacturing facilities

  • Data centers

  • Government buildings

  • Parking structures

  • Mechanical and electrical rooms

  • Industrial facilities

  • Fire alarm retrofit projects

  • Conventional and addressable fire alarm systems


The selected model must match the approved panel, communication circuit, wiring arrangement, operating requirement, and project specification.


Installation Considerations

Simplex manual pull stations should be installed only by qualified fire alarm personnel.

Before installation, verify:


  • Exact pull-station model

  • Addressable or conventional system requirement

  • Single-action or double-action operation

  • Compatible fire alarm control panel

  • IDNet or MAPNET II circuit compatibility

  • Conventional initiating circuit requirements

  • Required device address

  • Electrical-box type and dimensions

  • Surface, semi-flush, or flush mounting

  • Wiring size and polarity

  • Approved device location

  • Applicable listings and local requirements

  • Fire alarm drawings and cause-and-effect programming


Simplex documentation lists screw-terminal connections suitable for approximately 18 to 14 AWG wiring on the addressable models. The listed indoor operating temperature is 0°C to 49°C, with humidity up to 93% RH under the specified test condition.


Testing and Commissioning

After installation, each manual pull station should be tested as part of the complete fire alarm system.


Testing should confirm:

  • The pull station activates correctly

  • The correct address or zone appears at the panel

  • The programmed location description is accurate

  • Notification appliances activate as designed

  • Connected relays and control functions operate properly

  • The pull lever remains in the alarm position

  • The station resets using the correct key

  • The panel clears the alarm after reset

  • The system returns to normal condition

  • All controlled equipment follows the approved cause-and-effect sequence


For addressable models, verify the DIP-switch address and confirm that no duplicate device address is present on the communication circuit.


Maintenance and Inspection

Maintenance and inspection guide for a red fire alarm pull station, showing common issues such as loose screws, damaged housing, faded lettering, loose wiring, corrosion, moisture exposure, paint contamination, obstructed access, broken components, and incorrect mounting. Includes illustrated physical and electrical testing instructions.

Testing may be performed by physically operating the pull lever. Electrical testing can also be performed in accordance with the manufacturer’s instructions by unlocking the station housing and activating the alarm switch.


Common Installation Mistakes to Avoid


Avoid the following:

  • Selecting an addressable station for an incompatible panel

  • Connecting a conventional station directly to an addressable loop without a monitor module

  • Using the wrong device address

  • Installing duplicate addresses

  • Reversing communication-circuit wiring

  • Ordering the wrong operating type

  • Confusing single-action and double-action models

  • Installing an undersized electrical box

  • Mounting the device behind doors or obstructions

  • Painting the station

  • Failing to test controlled equipment

  • Resetting the station without investigating the alarm

  • Using unapproved replacement parts

  • Installing the device in an unsuitable outdoor or wet environment


Choosing the Correct Simplex Manual Pull Station


Choose the 4099-9004 when the project requires:

  • Addressable communication

  • Single-action pull-down activation

  • Direct individual device identification

  • Simple and immediate manual operation


Choose the 4099-9006 when the project requires:

  • Addressable communication

  • Double-action push-and-pull activation

  • Reduced risk of accidental operation

  • Individual device reporting at the fire alarm panel


Choose the 2099-9756 when the project requires:

  • Conventional circuit operation

  • Double-action push-and-pull activation

  • Replacement or expansion of a conventional system

  • Connection through an approved addressable monitor module when required


Source Simplex Manual Pull Stations from Pinoleakpes Enterprises Corporation


Pinoleakpes Enterprises Corporation supplies quality fire detection, fire protection, mechanical, and industrial system products, including Simplex addressable and conventional manual pull stations, smoke detectors, heat detectors, sensor bases, relay bases, modules, remote indicators, notification appliances, and fire alarm accessories.

Our team can assist contractors, engineers, consultants, installers, system integrators, building owners, and facility managers in selecting the appropriate Simplex 4099-9004, 4099-9006, or 2099-9756 Manual Pull Station based on the fire alarm control panel, communication protocol, activation method, mounting arrangement, project specification, and required system function.

Contact Pinoleakpes Enterprises Corporation for product availability, technical assistance, and quotation requirements.

Comments

Rated 0 out of 5 stars.
No ratings yet

Add a rating
footer banner.png
bottom of page